Skip to content

Country

24V 4kW Off-Grid Inverter For Solar System With MPPT Solar Charger

24V 2kW - 4k Off-Grid Inverter 

24V input, pure sine wave output, built-in MPPT solar charge controller, suitable for residential use.

TYCORUN produces multi power inverters that support seamless switching between solar and battery energy, ensuring continuous and stable power supply.

  • Monitoring platform for easy maintenance
  • Inner cooling system to keep a stable operation
  • Modular design easy to install and upgrade
  • Supporting medium power loads with continuous electricity
  • Cost-effective but high quality  for customers 

Quick Data 

 

 

 

Specs (1Kw - 3Kw Models) 

Model SF 1200 SE SF 2400 SE SF 3600 SE User-Settable
Nominal Battery Voltage 12Vdc 24Vdc 24Vdc
Battery Type Lithium LiFePO4/Lead-Acid/Flood /User Defined
PV INPUT
Nominal AC Input Voltage/Waveform 230Vac/Sinusoidal (Utility or Generator)
AC Input Range 90~280Vac (Appliances);170Vac~280Vac (UPS)
Nominal Input Frequency 50/60Hz (Auto Detection)
AC Input Frequency Range 40~65±1Hz  (>42 or <63±1Hz Comeback)
Max. Bypass Current 16Amp 20Amp 30Amp
Output Short Circuit Protection Circuit Breaker
Transfer Time 10ms Typical (UPS); 20ms Typical (Appliances)
AC CHARGER
Charging Algorithm 3-Step
Max. AC Charging Current 60Amp (@VI/P=230Vac) 60Amp (@VI/P=230Vac) 80Amp (@VI/P=230Vac)
Bulk Charging Voltage 14.6Vdc (AGM/Gel ) 14.1Vdc (Flooded ) 29.2Vdc (AGM/Gel ) 28.2Vdc (Flooded ) 29.2Vdc (AGM/Gel  ) 28.2Vdc (Flooded )
Floating Charging Voltage 13.5Vdc 27Vdc 27Vdc
Max. Hybrid Charging Current (Solar & Utility) 60Amp 60Amp 80Amp
PV INPUT
Num. of Independent MPPT Tracker 1 1 1
MPPT Input Current 1*11Amp 1*11Amp 1*18Amp
Max. PV Array Power 2000W 3000W 4000W
Max. Solar Charge Current 60Amp 60Amp 80Amp
PV Array MPPT Voltage Range 30~400Vdc 30~400Vdc 30~400Vdc
Max. PV Array Open Circuit Voltage 450Vdc 450Vdc 450Vdc
MPPT Tracking Efficiency 99.9% 99.9% 99.9%
INVERTER OUTPUT
Num. of Output Ports 1 1 1
Rated Output Power 1200W 2400W 3600W
Max. Output Current 5.2A 10.4A 15.7A
Surge Capacity 2400VA/2400W for 5 Seconds 4800VA/4800W for 5 Seconds 7200VA/7200W for 5 Seconds
Output Voltage Waveform Pure Sine Wave
Overload Protection 5s@150% Load; 10min@110%~150% Load
Output Voltage 220/230/240 Vac ± 5%
Output Frequency 50Hz/60Hz ±1 Hz
Peak Efficiency 92% 93% 94%
Low Voltage Cut-off Voltage 10.5Vdc 21.0Vdc 21.0Vdc
High Voltage Cut-off Voltage 16.0Vdc 33.0Vdc 33.0Vdc
Cold Start Voltage (When Only Connect with Battery) 11.5Vdc 23.0Vdc 23.0Vdc
No Load Power Consumption <25W@12Vdc <35W@24Vdc <35W@24Vdc
Parallel Capacity NO NO NO
GENERAL
Operating Temperature Range -10°C~55°C
Storage Temperature -15°C~60°C
Humidity 5% to 95% Relative Humidity (Non-Condensing)
Altitude <2000m
Noise ≤60dB
Protection Degree IP21,Indoor OnIy
Cooling Method Intelligent Fan
Dimensions(W*H*D) 355*280*110 mm 355*280*110 mm 355*309*110 mm
Weight 5.7 KG 6.1 KG 7.3 KG
Warranty 2 Years 2 Years 2 Years
COMMUNICATION
Embedded Interface RS232*1
Work with Bluetooth Monitoring Dongle (Optional) YES, by RS232
Work with Lithium Battery BMS NO
CERTIFICATION
Certification/Standard CE(IEC61000,IEC62109) ; IEC61683,IEC60068 ; RoHS

 

Downloads

Spec Sheet 1.2/2.4/3.6 Kw 
Spec Sheet 4Kw Unit

 

Specs (4Kw Model Only) 

Model SF 4000 User- Settable
Nominal Battery Voltage 24Vdc
Battery Type Lithium LiFePO4/Lead-Acid/Flood /User Defined
AC INPUT
Nominal AC Input Voltage/Waveform 230Vac/Sinusoidal (Utility or Generator)
AC Input Range 90~280Vac (Appliances);170Vac~280Vac (UPS)
Nominal Input Frequency 50/60Hz (Auto Detection)
AC Input Frequency Range 40~65±1Hz  (>42 or <63±1Hz Comeback)
Max. Bypass Current 30Amp
Output Short Circuit Protection Circuit Breaker
Transfer Time 10ms Typical (UPS); 20ms Typical (Appliances)
AC CHARGER
Charging Algorithm 3-Step
Max. AC Charging Current 100Amp (@VI/P=230Vac)
Bulk Charging Voltage 29.2Vdc (AGM/Gel Battery);28.2Vdc (Flooded Battery)
Floating Charging Voltage 27Vdc
Max. Hybrid Charging Current (Solar & Utility) 120Amp
PV INPUT
Num. of Independent MPPT Tracker 1
MPPT Input Current 1*22Amp
Max. PV Array Power 6000W
Max. Solar Charge Current 120Amp
PV Array MPPT Voltage Range 60~450Vdc
Max. PV Array Open Circuit Voltage 500Vdc
MPPT Tracking Efficiency 99.9%
INVERTER OUTPUT
Num. of Output Ports (Main & Second Output) 2
Rated Output Power of Main/Second Output*【1】 4000W/4000W
Max. Output Current of Main/Second Output 17.4A/17.4A
Surge Capacity 8000VA/8000W for 5 Seconds
Output Voltage Waveform Pure Sine Wave
Overload Protection 5s@150% Load; 10min@110%~150% Load
Output Voltage 220/230/240 Vac ± 5%
Output Frequency 50Hz/60Hz ±1 Hz
Peak Efficiency 94%
Low Voltage Cut-off Voltage 21Vdc
High Voltage Cut-off Voltage 33Vdc
Cold Start Voltage (When Only Connect with Battery) 23Vdc
No Load Power Consumption <35W@24Vdc
Parallel Capacity NO
GENERAL
Operating Temperature Range -10°C~55°C
Storage Temperature -15°C~60°C
Humidity 5% to 95% Relative Humidity (Non-Condensing)
Altitude <2000m
Noise ≤60dB
Protection Degree IP21,Indoor OnIy
Cooling Method Intelligent Fan
Dimensions(W*H*D) 415*309*110 mm
Weight 9.5 KG
Warranty 2 Years
COMMUNICATION
Embedded Interface RS232*1/RS485*1/Dry Connection
Work with Bluetooth Monitoring Dongle (Optional) YES, by RS232
Work with Lithium Battery BMS YES, by RS485
CERTIFICATION
Certification/Standard CE(IEC61000,IEC62109) ; IEC61683,IEC60068 ; RoHS
by Tycorun
Original price $349.00 - Original price $949.00
Original price
$349.00
$349.00 - $949.00
Current price $349.00
Wattage: 12v 1.2kW Off-Grid Solar Inverter